Plan Review and Construction Compliance Goal:
- Provide quality service to our clients by being efficient, flexible, responsive and accountable,
- Review plans, specifications, and
- Observe health care facilities construction to ensure compliance with applicable codes and regulations.
Activities & Processes
FDD Links
- FDD Home
- FDD General / About FDD
- What's New?
- Project Status
- eServices Portal Client Access
- Forms, Applications, and Instructions
- Code Application Notices (CANs) and Policy Intent Notices (PINs)
- Regulation Codes, Interpretations, and Policies
- Legislation
- Pre-Approvals
- Construction Observation and Building Permits
- Hospital Inspector Certification Program (HICP)
- Plan Review
- Seismic Compliance
- Hospital Building Safety Board (HBSB)
- Licensed Clinics
- Frequently Asked Questions (FAQs)
- Additional Information/Resources
- Quality of Service Survey
- Email the Ombudsman
- Site Map
Plan Approval w/Comments
On October 1, 1997, the Facilities Development Division in the Office of Statewide Health Planning and Development (OSHPD) began the "Approved with Comments" procedure. This procedure is designed to:
- Reduce plan review "turnaround" time.
- Reduce the number of backchecks.
- Reduce the time required to issue a Plan Approval Letter and a Building Permit.
Plan review and field staff are allowed to:
- Conditionally approve plans with comments marked on the plans and specifications.
- Determine which type of comments to mark on the plans and specifications.
- Incorporate comments into the approved documents. These comments cannot relate to the safety of construction or design.
After the documents are approved with comments, OSHPD issues a Plan Approval Letter and a conditional Building Permit. At a later date, a Compliance Officer, a Field Fire and Life Safety Officer, a District Structural Engineer, or an Office Plan Reviewer will review and clear all comments. This review can be done at the construction site, the OSHPD office, or the office of the Architect or Engineer of Record. The Architect or Engineer of Record is responsible for ensuring the approved documents with comments are available at the job site at all times. All comments must be cleared before construction can occur in the area relating to the comments. The Compliance Officer will not issue the 100% completion report unless all comments have been cleared.
Standard Comments
Below are standard comments prepared and used by the FDD Plan Checkers to assist in more efficient and consistent plan checks. Adobe Acrobat Reader is required for the portable document format (pdf) documents below.
Architectural Comments
Electrical Comments
Structural Comments
- Standard Structural and Anchorage Review Comments per
1995 California Building Code (AKA 0619)
Applicable to single-story Type V skilled nursing or intermediate care facilities utilizing wood-frame or light steel-frame construction for projects received after December 29, 1995. - Standard Structural and Anchorage Review Comments per 1995 2001
California Building Code (AKA 0621)
Applicable to hospital buildings for projects received after December 29, 1995 November 1, 2002 - Standard Structural and Anchorage Review Comments in accordance with the 2007 California Building Code (2007 CBC)
Applicable to hospital buildings for projects received after October 1, 2008. - Standard Structural and Anchorage Review Comments in accordance with the 2007 California Building Code (2007 CBC)
Applicable to single-story Type V skilled nursing or intermediate care facilities utilizing wood-frame or light steel-frame construction for projects received after October 1, 2008. - Standard Structural Review Comments in accordance with the 2010 California Building Standards Code (2010 CBSC)
Applicable to OSHPD 1 projects for hospital buildings received after January 1, 2011. - Standard Structural Review Comments in accordance with the 2010 California Building Standards Code (2010 CBSC)
Applicable to OSHPD 2 projects for single-story Type V skilled nursing or intermediate care facilities utilizing wood-frame or light-steel frame construction received after January 1, 2011. - Standard Geotechnical Report Review Comments in accordance with the 2010 California Building Standards Code (2010 CBSC)
Applicable to OSHPD 1 projects for hospital buildings received after July 1, 2011. - Standard Structural Review Comments in accordance with the 2013 California Building Standards Code (2013 CBSC)
Applicable to OSHPD 1 projects for hospital buildings received after January 1, 2014. - Standard Structural Review Comments in accordance with the 2013 California Building Standards Code (2013 CBSC)
Applicable to OSHPD 2 projects for single-story Type V skilled nursing or intermediate care facilities utilizing wood-frame or light-steel frame construction received after January 1, 2014. - Standard Geotechnical Report Review Comments in accordance with the 2013 California Building Standards Code (2013 CBSC)
Applicable to OSHPD 1 projects for hospital buildings received after January 1, 2014.